polobi.blogg.se

Instacal manual
Instacal manual








instacal manual
  1. #INSTACAL MANUAL MANUALS#
  2. #INSTACAL MANUAL INSTALL#
  3. #INSTACAL MANUAL DRIVER#
  4. #INSTACAL MANUAL PRO#

A USB-1608FS is shown in this example.Ĭlick OK to add the device to the configuration file. The Plug and Play Board Detection dialog shows the installed MCC USB devices detected by InstaCal. Run InstaCal from the Start✺ll Programs»Measurement Computing menu.

instacal manual

#INSTACAL MANUAL MANUALS#

All MCC user guides are available on the Measurement Computing Data Acquisition Software CD that came with your device, and they are also on the MCC Product User's Manuals page at Run InstaCal and add your USB device To run InstaCal and add your MCC USB device to the InstaCal configuration, complete the following steps. Connect the wires from the device to the signal source so that the device acquires signals from analog channel 0.

#INSTACAL MANUAL INSTALL#

Install and connect your MCC USB device to its signal source Refer to your MCC device user's guide for instructions on installing and connecting to an analog signal source. Run icalsetup.exe to extract the installation files and install the latest version of InstaCal. 1.Ĭlick on the Download InstaCal link on the Software/Drivers Downloads page at to download icalsetup.exe. For versions earlier than 6.23, exit InstaCal and continue to follow the steps for downloading and installing InstaCal. For version 6.23 or later, exit InstaCal and proceed to the section Install and connect your MCC USB device to its signal source. Select Help✺bout InstaCal… to see what version is installed. If you have already installed InstaCal If you have already installed InstaCal from the Measurement Computing Data Acquisition Software CD that came with your device, run InstaCal from the Start✺ll Programs»Measurement Computing menu. You must be logged in as an administrator to install InstaCal. Quick Start: Using DASYLab with a Measurement Computing USB deviceĭownload and install InstaCal Follow these steps to install the latest version of InstaCal.

#INSTACAL MANUAL PRO#

Windows 7 32-bit Windows 7 64-bit (as 32-bit application) Windows Vista 32-bit, with Service Pack 2 Windows Vista 64-bit (as 32-bit application) Windows XP Pro with Service Pack 3 Operating Systems You must have administrator rights on your account using one of the following operating systems:      Hardware CPU - x86 compatible processor, 1 GHz or more RAM - At least 1 GB, 2 GB recommended Hard disk space - 250 MB free storage space, of which at least 200 MB on the system partition Graphics board - Color depth at least 16-bit (High Color), recommended 24- or 32-bit (True Color) Screen resolution - At least 1024 × 768

instacal manual

You can download the DASYLab evaluation, InstaCal, and any software updates and service packs from the Software/Drivers Downloads page at System requirements DASYLab 12.0.1 requires the following minimum hardware and operating system requirements.

#INSTACAL MANUAL DRIVER#

Please read this document completely before you install any software or hardware.ĭASYLab 12.0.1 (purchased version or evaluation license) MCC InstaCal driver and utility software (version 6.23 or later) Instructions on installing and using InstaCal are included below. You must first configure your MCC USB device with InstaCal – the installation, calibration, and test utility for MCC hardware – before you can use it with DASYLab. DASYLab is an icon-based data acquisition, graphics, control, and analysis software package. This Quick Start document contains the latest information on downloading, installing, and using DASYLab version 12.0.1 and the MCC-DRV driver with your USB device. Quick Start Using DASYLab with your Measurement Computing USB device Thank you for purchasing a USB data acquisition device from Measurement Computing Corporation (MCC).










Instacal manual